Data Center Power & Energy Storage Solution

Data centers cannot tolerate even milliseconds of power loss. XGW's data center power solution spans the full DC power chain: 48V LiFePO4 rack batteries with 6,000+ cycles for edge facilities, high-voltage UPS battery strings (192V/384V/409V) for central UPS systems, DIN rail PSUs with DC-OK signaling for rack-level control power, and enclosed PSUs for server and networking equipment. Smart BMS telemetry over RS485/CAN integrates with DCIM platforms for real-time battery health monitoring.

XGW data center power solution with server racks and LiFePO4 battery backup cabinets

Core Components

How It Works

  1. 48V rack-level backup. LiFePO4 telecom batteries (50-200Ah) drop into 19-inch racks for edge data centers and distributed IT rooms. 6,000+ cycle life at 80% DoD means 10-15 years of service — matching server refresh cycles and eliminating mid-life battery replacement.
  2. Central UPS string replacement. High-voltage LiFePO4 UPS strings (192V/384V/409V) replace VRLA in central UPS systems with 3-4x cycle life, 1/3 the volume and 1/2 the weight. Active balancing BMS with CAN/RS485 interfaces reports SOC, SOH and alarm states to the UPS host and DCIM platform.
  3. Rack control power with redundancy. DIN rail PSUs deliver clean 24V/48V for rack-level controllers, sensors and management modules. DC-OK relay contacts convert silent power failures into logged alarms. N+1 parallel redundancy ensures no single point of failure in control voltage.
  4. Thermal and efficiency management. Enclosed PSUs up to 94% efficiency minimize heat load on data center cooling. Fanless convection models suit noise-sensitive edge deployments. -30C to +70C operation covers unmanned and outdoor cabinet installations.
  5. DCIM integration. Smart BMS telemetry (RS485/CAN/Modbus) feeds battery voltage, current, SOC, SOH and cell temperature data directly into DCIM and BMS monitoring platforms — enabling predictive maintenance and capacity planning from real data, not estimates.

Need a Custom Power Solution?

37 senior R&D engineers. OEM/ODM from 500 units. Samples in 3-7 days.

Get a Quote WhatsApp Us

High Rate Lithium Battery for Industrial UPS

Industrial UPS carries motor and IT loads with sharp inrush, so the high rate lithium battery for industrial UPS has to deliver current without sagging. XGW's lithium packs support up to 6C peak discharge, drop into existing UPS cabinets as VRLA replacements across 48V-409V, and report through CAN/RS485 with cell-level BMS supervision.

RangePeak rateDrop-in
48V - 409Vup to 6CVRLA replacement

Product: UPS lithium battery. For project sizing see custom battery pack.

What battery does an industrial UPS use?

A high-rate lithium pack — up to 6C at XGW — that holds voltage through inrush where VRLA sags.

Why Choose XGW for Data Center Power

XGW battery systems are already running in demanding data center and hospital environments. Our 384V 200Ah LiFePO4 UPS strings — built with CATL / BYD / EVE Grade-A cells and UN38.3 certified — are deployed in 5-unit batches for critical infrastructure across Saudi Arabia and South Africa, engineered for high-ambient reliability and protocol-matched to the UPS host.