384V 200Ah LiFePO4 UPS Battery for Data Centers & Hospitals in Saudi Arabia

Battery ESSUPSData CenterHospital

The Challenge

The Solution

XGW 384V 200Ah LiFePO4 UPS battery cabinet, five-module rack with high-voltage busbars and BMS communication interface.
384V 200Ah LiFePO4 UPS battery cabinet prepared for shipment — five-module rack, integrated BMS, protocol-matched to the UPS host.

VRLA Baseline vs LiFePO4 (200Ah)

ItemTypical VRLA bankLiFePO4 as supplied (200Ah)
ChemistryVRLA lead-acidLiFePO4 (CATL / BYD / EVE Grade-A)
Nominal voltage384V DC384V DC (120S LiFePO4)
Capacity200 Ah200 Ah (76.8 kWh per string)
Communication with UPS hostTerminal voltage sensing onlyModbus RTU-TCP over RS485, CAN optional
Data available to UPSTerminal voltage onlySOC, SOH, cell voltage, cell temperature, alarms
Behaviour at 45-50℃ ambientAccelerated ageing, capacity fadeBMS-managed, charge current derated by temperature
Transport certificationn/aUN38.3

Results

  1. Deployed in 5-unit batches across Saudi data center and hospital sites, with a total installed capacity of approximately 384 kWh per site (5 × 76.8 kWh strings).
  2. The installation is engineered for Gulf ambient temperatures: the BMS derates charge current as cell temperature rises, which is the behaviour that protects cycle life through sustained heat.
  3. Because the BMS speaks the UPS host's protocol, battery state is reported straight into the UPS and monitoring platform — no separate battery panel to maintain.

Related Product

Case Study FAQ

Why is the UPS battery voltage 384V?

384V DC is a common DC-bus voltage for mid-to-large UPS systems. In LiFePO4 terms it is 120 cells in series (120 x 3.2V nominal = 384V), which lets the pack replace a VRLA string of the same nominal voltage without modifying the UPS.

Which cells are used in the 384V 200Ah string?

The string is built with Grade-A LiFePO4 cells from Tier-1 suppliers (CATL, BYD, EVE). Grade-A prismatic cells give consistent internal resistance and cycle behaviour, which matters most when five units run in parallel at a single site.

Can a LiFePO4 string replace VRLA without changing the UPS?

Usually yes, provided three things match: the nominal voltage band, the charge profile the UPS expects, and the communication protocol. We configure the BMS to the host's protocol so the UPS recognises the pack and can report SOC and alarms.

How does the system handle 45-50°C Gulf ambient?

VRLA life drops sharply above its 25°C design point — roughly halved for every 8-10°C rise. The LiFePO4 pack uses high-temperature-tolerant cells with a BMS that derates charge current as cell temperature climbs and forces active ventilation, so the pack tolerates sustained Gulf heat instead of ageing out of it.