Modular Three-Phase UPS
50–720 kVA hot-swappable modular systems (380V, 480V and 208V platforms). Scale from a single rack to 2.0 MVA for mega data centers, hospitals and semiconductor fabs.
View systems →XGW builds online double-conversion UPS systems from 1 kVA to 720 kVA — modular, tower and rack — and pairs them with LiFePO4 UPS battery cabinets. Engineered for data centers, hospitals, semiconductor fabs, industrial automation and telecom, where a single transfer matters.
Request a Quote Explore Product Lines WhatsApp
50–720 kVA hot-swappable modular systems (380V, 480V and 208V platforms). Scale from a single rack to 2.0 MVA for mega data centers, hospitals and semiconductor fabs.
View systems →120–600 kVA three-phase tower UPS plus 1–40 kVA rack and single-phase units. Wide input range, 3-level topology and full DSP control for harsh-grid SCADA, automation and edge sites.
View systems →384V / 480V / 512V LiFePO4 cabinets with CATL, BYD and EVE cells and active balancing BMS. Drop-in replacement for VRLA strings — half the weight, 3–4× the cycle life.
View cabinets →XGW designs the UPS, the LiFePO4 cabinet and the industrial PSU on the same power-electronics platform. One OEM/ODM partner for the whole critical-power chain, not a box assembler reselling someone else's batteries.
Our UPS strings and LiFePO4 cabinets are sized against the same DC bus. Send us your load and runtime and we deliver a matched UPS + battery cabinet, not two products that have to be reconciled in the field.
Online double conversion with input PF > 0.99 and THDi < 3% protects upstream generators and utility feeds, while output PF = 1 and THDu < 1% keeps sensitive medical and automation loads clean.
Modular systems carry hot-swappable power modules and a 7–10 inch touch LCD with IoT functions. SNMP, AS400, parallel and LBS options integrate with DCIM and building management.
Online double-conversion systems from 1 kVA to 720 kVA across modular, tower and rack forms, plus LiFePO4 UPS battery cabinets at 384V / 480V / 512V. Tell us the load, runtime and DC bus and we map the configuration.
Yes. XGW builds both the UPS and the LiFePO4 battery cabinet on the same platform, so the DC bus, charge profile and BMS telemetry are matched. VRLA-to-LiFePO4 retrofit is also supported.
The UPS lines are built to IEC 62040-1 and IEC 60950-1 (safety), IEC 62040-2 (EMC) and the IEC 61000-4 EMC family (ESD, RF, EFT, surge). Battery cabinets carry UN38.3 and IEC 62619.
Modular frames accept hot-swappable power modules and parallel into systems up to 2.0 MVA, so capacity grows with the rack build-out without replacing the base cabinet.
48V–409V LiFePO4 strings with active balancing BMS.
48V LiFePO4 for base stations and edge sites.
Solution page: UPS, battery and thermal for critical facilities.
37 senior R&D engineers. OEM/ODM from 500 units. Samples in 3-7 days.
Get a Quote WhatsApp Us