UPS Lithium Battery Cabinets — 384V / 480V / 512V

LiFePO4 cabinets with CATL, BYD and EVE Grade-A cells and an active balancing BMS. Drop-in replacement for VRLA strings in data center and industrial UPS — half the weight, 3–4× the cycle life, up to 6C peak discharge.

Request a Quote Configure a Rack WhatsApp
384V / 480V / 512VCATL / BYD / EVEUp to 6CUN38.3 / IEC 62619

Why Replace VRLA With LiFePO4 in UPS

LiFePO4 vs VRLA for UPS
Cycle life6,000+ cycles300–500 cycles
Footprint~50% of VRLA stringLarge, heavy racks
MaintenanceNear-zeroAnnual test, periodic swap
10-yr TCOLower (no swap labor)Higher (battery + labor)
Best forEdge / modular UPSLegacy float plants

Cabinet Range

UPS lithium battery cabinet range
384V series50 / 100 / 200 Ah · 200Ah = 76.8 kWh · 92.2 kW sustained
480V seriesFour capacity steps, 28.8–134.4 kWh · 1.0C–5.0C
512V 100Ah4.5C · high-rate, Gotion cells · UL 9540A module test
CellsGrade-A LiFePO4: CATL / BYD / EVE
BMSActive balancing, overcharge/over-discharge/over-current/short/thermal
CommunicationCAN / RS485 to UPS host and DCIM
ComplianceCE, RoHS, UN38.3, IEC 62619

How To Configure a 384V Rack for a 100kW UPS

A 100kW UPS on a 384V DC bus draws roughly 260A. A 384V 200Ah LiFePO4 cabinet delivers 76.8 kWh and sustains that current with headroom; parallel cabinets extend runtime. The active balancing BMS reports SOC, SOH and alarms over CAN/RS485 to the UPS and DCIM. Send us the UPS model, DC bus and required backup minutes and we size the rack.

Applications

Data centers

High-reliability LiFePO4 backup for IT loads. 6,000+ cycles and active balancing BMS ensure dependable power through thousands of discharge events over a 15-year service life.

Hospitals & healthcare

Life-safety backup for medical facilities. Low-leakage design and IEC 62619 safety certification support healthcare code compliance.

Industrial UPS

Process-critical backup for manufacturing, oil & gas and chemical facilities. Up to 6C peak covers UPS inrush and high peak loads.

Financial & infrastructure

Zero-downtime backup for trading floors, ATMs and transportation signaling. CAN telemetry integrates with DCIM.

Frequently Asked Questions

How do I configure a 384V LiFePO4 battery rack for a 100kW data center industrial UPS?

A 100kW UPS on a 384V DC bus needs roughly 100kW of battery power. At 384V that is about 260A; a 384V 200Ah LiFePO4 cabinet delivers 76.8kWh and sustains the current with headroom, and multiple cabinets parallel for longer runtime. XGW builds the rack with an active balancing BMS reporting SOC, SOH and alarms over CAN/RS485 to the UPS host and DCIM. Send us the UPS model, DC bus and required backup minutes and we size the rack.

Can the LiFePO4 cabinet replace VRLA without changing the UPS?

In most cases yes. XGW cabinets are built to the same voltage windows as the VRLA string they replace, and the BMS handles balancing and protection. The one thing to verify is the charger voltage and current against the LiFePO4 charge profile, so send us the UPS model and we confirm the fit before you order.

Which cells does XGW use in the UPS cabinets?

Grade-A LiFePO4 cells from CATL, BYD and EVE. The same cell sourcing backs XGW telecom and ESS batteries, so the critical-power chain comes from one supply base.

Related Products

Need a Critical Power Solution?

37 senior R&D engineers. OEM/ODM from 500 units. Samples in 3-7 days.

Get a Quote WhatsApp Us