Industrial & Tower UPS — 1 to 600 kVA

Three-phase tower and rack UPS plus single-phase units for SCADA, automation, ports and weak-grid sites. Wide input range and full DSP control keep PLC and process loads alive through sags, swells and frequency drift.

Request a Quote Technical Specs
1–600 kVATower / Rack3-phase & single-phase> 96% efficiency

Engineered for harsh grids

  • Online double conversion, 3-level topology
  • Wide input range, full DSP control
  • Intelligent battery management
  • Auto fault recording & self-aging
  • Half-wave load support
  • IEC 62040-1, 60950-1, 62040-2, 61000-4

Product Range

Industrial and tower UPS range
HN33 Series120–600 kVA · 3-phase tower · > 96% efficiency
HNR33 Series10–40 kVA · 3-phase rack · 30 kW in 3U, 19-inch
HN31 / HNR3110–20 kVA · 3/1 single-phase tower & rack
HN11 / HNR116–20 kVA · single-phase tower & rack (10 kW in 2U)
1–3 kVASingle-phase tower & rack · up to 95.5% efficiency

Key Features

Technical Specifications (HN33 120–600 kVA tower)

HN33 tower UPS technical specifications
Operation3P/3P online double conversion
Main input3P5W (3P+N+PE), 380/400/415V L-L, 50/60Hz
Input PF / THDi> 0.99 / < 3% at full linear load
Output PF / accuracy1 / ±1.0%
EfficiencyNormal & battery mode ≥ 96%
Overload110% long · 125% 10min · 130% 1min · >150% 300ms
IP degreeIP20
Noise72 dB @ 100% load, 69 dB @ 45% load
ComplianceIEC 62040-1, IEC 60950-1, IEC 62040-2, IEC 61000-4-2/3/4/5
Cabinet size600×1000×1600 to 1200×1100×2000 mm

Applications

SCADA & automation

Three-phase rack UPS (HNR33, 10-40 kVA) mounts beside the PLC in a 19-inch cabinet. Wide input range and full DSP control ride through weak-grid sags and swells that would drop a cheaper offline unit.

Oil & gas, ports, power plants

HN33 tower UPS (120-600 kVA) backs control rooms and safety systems with >96% efficiency and seamless online-islanding during grid events.

Edge & single-phase loads

HN11/HNR11 (6-20 kVA) and 1-3 kVA units protect small server rooms, ATMs and remote telemetry with up to 95.5% efficiency and a 110-300V input range.

Process & manufacturing

Output PF = 1 and <1% THDu keep variable-frequency drives and sensitive instruments clean; auto fault recording supports post-event analysis.

Pair With a Matched Battery Cabinet

For long, maintenance-light backup on weak grids, pair the UPS with a LiFePO4 cabinet on the matched DC bus — 384V, 480V or 512V. See the UPS Lithium Battery Cabinets page.

Frequently Asked Questions

How do I configure industrial UPS for SCADA and harsh-grid sites?

For SCADA and automation, choose a three-phase tower or rack UPS with a wide input voltage range and full DSP control so it rides through sags, swells and frequency drift on a weak industrial grid. XGW HN33 (120-600 kVA) runs >96% efficiency and the rack units (HNR33, 10-40 kVA) mount in a 19-inch cabinet beside the PLC. Pair the UPS with a LiFePO4 cabinet on the matched DC bus for long, maintenance-light backup.

Which UPS covers small and edge loads?

For edge and single-phase loads, XGW offers 6-20 kVA single-phase tower (HN11) and rack (HNR11) units, plus 1-3 kVA tower/rack with up to 95.5% efficiency and a 110-300V input range. All are online double-conversion with output PF = 1.

What protects the load during a transfer?

Online double conversion isolates the load from the raw grid at all times, so transfers are seamless. Tower and rack units carry overload and short-circuit protection with automatic fault recording for post-event analysis.