Modular Three-Phase UPS — 50 to 720 kVA

Hot-swappable, online double-conversion modular UPS for data centers, hospitals and semiconductor fabs. Build N+X redundant capacity from a single frame and parallel frames up to 2.0 MVA as the load grows.

Request a Quote Technical Specs
380V / 480V / 208VN+X redundancyHot-swappable modulesUp to 2.0 MVA

Built for mega data centers

  • Online double conversion, 3P/3P
  • Input PF > 0.99, THDi < 3%
  • Output PF = 1, THDu < 1%
  • 7–10 in touch LCD + IoT
  • SNMP / AS400 / Parallel / LBS
  • IEC 62040-1, 60950-1, 62040-2, 61000-4

Modular UPS Platforms

Modular three-phase UPS platform range
HM Series50–600 kVA · 380/400/415V · 30 kW modules in 2U
HMH Series60–720 kVA · 480V · up to 1.8 MVA per system
HML Series18–360 kVA · 208V · 2U high-density modules

Key Features

Technical Specifications (HM 50–600 kVA platform)

HM modular UPS technical specifications
Operation3P/3P online double conversion
Main input3P5W (3P+N+PE), 380/400/415V L-L, 50/60Hz
Input PF / THDi> 0.99 / < 3% at full linear load
Output PF / accuracy1 / ±1.0%
Output THDu< 1% linear, < 5% non-linear (IEC 62040-3)
Overload (inverter)110% 1h · 125% 10min · 150% 1min · >150% 200ms
DisplayLED + 7/10 inch touch LCD
IP degreeIP20
Noise72 dB @ 100% load, 69 dB @ 45% load
Environment0–40°C op, −25–70°C storage, 0–95% RH non-condensing
ComplianceIEC 62040-1, IEC 60950-1, IEC 62040-2, IEC 61000-4-2/3/4/5
Module / cabinet size442×659×174 mm module; 600×1000×1600 to 1200×1100×2000 mm cabinet

Applications

Data centers & colocation

Parallel modular frames up to 2.0 MVA with N+X redundancy. Hot-swappable modules mean capacity scales with the rack build-out and a faulted module is replaced without dropping the load.

Hospitals & healthcare

Life-safety backup for ICU, imaging and operating theaters. Online double conversion and <1% THDu protect sensitive medical loads; SNMP telemetry feeds the facility BMS.

Semiconductor & cleanroom

Zero-millisecond transition and precise output regulation keep process lines and lithography tools within tolerance through grid events.

Finance & government

Continuous heavy loads with input PF > 0.99 reducing generator and utility strain; LBS option coordinates multiple UPS on a shared bus.

Pair With a Matched Battery Cabinet

XGW modular UPS ships with a matched LiFePO4 battery cabinet on the same DC bus — 384V, 480V or 512V — with an active balancing BMS. See the UPS Lithium Battery Cabinets page, or start from the Critical Power hub.

Frequently Asked Questions

What is the difference between modular UPS and traditional monolithic UPS in critical infrastructure?

A monolithic UPS is a fixed-capacity box; a failure or capacity increase means swapping a whole unit. A modular UPS builds capacity from hot-swappable power modules inside one frame. For critical infrastructure the difference is redundancy and scaling: N+X modular lets a module fail or be serviced without dropping the load, and you add modules as the data center grows instead of installing a bigger box. XGW modular frames parallel into systems up to 2.0 MVA.

Which modular platform covers my site voltage?

XGW modular three-phase UPS spans 380V (50-600 kVA), 480V (60-720 kVA) and 208V (18-360 kVA) platforms, all online double-conversion with input PF > 0.99 and THDi < 3%. Pick the platform matching your utility and load voltage; the battery cabinet is then matched to the same DC bus.

How is redundancy and monitoring handled?

Modules run in N+X with automatic isolation on fault. A 7-10 inch touch LCD with IoT functions plus SNMP, AS400, parallel-kit, SPD and LBS options integrate the UPS with DCIM and building management.