Modular UPS Systems — 50 to 720 kVA
Answer: A modular UPS is an online double-conversion system built from hot-swappable power modules in a shared frame. XGW frames span 50–720 kVA with N+X redundancy and parallel to 2.0 MVA — capacity grows in steps, and a failed module is swapped without dropping the load.
A modular UPS is an online double-conversion system built from hot-swappable power modules in a shared frame. XGW frames span 50–720 kVA with N+X redundancy and parallel to 2.0 MVA — capacity grows in steps, and a failed module is swapped without dropping the load.
How a Modular UPS Is Built
A modular UPS is built from a common frame containing the static switch, control module and DC bus, plus hot-swappable power modules that each carry a full online double-conversion rectifier and inverter. The frame sizes the installation; the modules size the capacity. XGW offers three platforms: the HM series (50–600 kVA, 380/400/415V, 30 kW modules in 2U), the HMH series (60–720 kVA, 480V, up to 1.8 MVA per system) and the HML series (18–360 kVA, 208V, high-density modules).
Why Modular UPS Scales Better
A monolithic UPS is one fixed power block — expand it means adding another whole unit. A modular type UPS grows by adding modules inside the same frame, and N+X redundancy means one module can fail or be serviced while the load stays online. Capacity can be added without replacing the cabinet, switchgear or battery investment. For facilities whose load doubles, that difference decides the ten-year cost.
Technical Specifications
| Power range | 50–720 kVA per frame; parallel to 2.0 MVA |
|---|---|
| Topology | Online double conversion, 3P/3P (VFI per IEC 62040-3) |
| Power modules | Hot-swappable; HM 30 kW in 2U |
| Input | 380/400/415V, 480V or 208V platforms; PF > 0.99, THDi < 3% |
| Output | PF = 1, accuracy ±1%, THDu < 1% linear |
| Redundancy | N+X with automatic fault isolation |
| Monitoring | 7–10 in touch LCD, SNMP, AS400, parallel kit, LBS |
| Compliance | IEC 62040-1, IEC 62040-2, IEC 61000-4 |
| Design life | 10–20 years; IP20; 0–40°C operation |
Applications
Data centers & colocation
Parallel modular frames up to 2.0 MVA with N+X. Capacity scales with the rack build-out; a faulted module is swapped without dropping the load.
Hospitals & healthcare
Life-safety backup for ICU, imaging and operating theaters. Output PF = 1 and THDu < 1% keep sensitive medical loads clean.
Semiconductor fabs
Zero-millisecond transition and stable output for sensitive process lines where a sag means a scrap lot.
Industrial & process
Wide input tolerance and hot-swap service keep PLC and SCADA loads alive on weak grids.
Pair With a Matched Battery Cabinet
IEC 62040 certified · 37 R&D engineers · samples in 3–7 days. LiFePO4 battery cabinets at 384V/480V/512V matched on the same DC bus with protocol-matched BMS (CAN/RS485). We confirm compatibility against your UPS model before order — no universal plug-and-play claim.
Frequently Asked Questions
What is a modular UPS?
A modular UPS is an online double-conversion UPS built from hot-swappable power modules that share one frame and battery system. Capacity and N+X redundancy grow by adding modules, and a failed module is replaced without transferring the load to bypass.
Is a modular UPS better than a monolithic UPS?
For growing or high-availability loads, yes: modules let capacity scale in steps and one module can fail without dropping the load. For a small fixed load and tight budget, a monolithic unit has lower upfront cost.
What power range do modular UPS systems cover?
XGW modular three-phase frames span 50–720 kVA across 380V, 480V and 208V platforms, paralleling to 2.0 MVA. Single-phase modular options cover smaller edge loads.
Can I add capacity later?
Yes. That is the core advantage of a modular UPS system — add power modules inside the existing frame as the load grows, without replacing the cabinet or switchgear.
How is battery backup matched?
The LiFePO4 battery cabinet is sized on the same DC bus (384V/480V/512V) with protocol-matched BMS over CAN/RS485. We confirm the fit against your UPS model before order; no universal plug-and-play claim.
Related Pages
Get a Quote
37 R&D engineers · OEM/ODM custom & project development, no MOQ · standard volume from 500 units · samples in 3–7 days.
Get a QuoteWhatsApp